Horizontal Laminar Flow Cabinet (Exclusive)
Click to Enlarge
Horizontal Laminar Flow Cabinet (Exclusive)

Interlabs offers a comprehensive range of high performance Horizontal, Laminar Flow Clean Air Cabinets. Modular construction, combining aesthetic appeal with functional utility and efficiency. These are designed to meet the filtration, illumination, Noise & Vibration requirements and US Federal Standard 209 B (BS 5295), providing air to meet class 100 (class I) conditions, to the extent applicable.
Ideal for microbiological manipulations, work with bioassays sterility testing & research work, vial filling & bunging operation in parenteral units & for general dry-processing work in semiconductor industry etc. Provides a comfortable ?sit down? working position for the operators.

Construction :? All Laminar Flow Clean Air cabinets are basically constructed out of thick teak wood board, which is termite and insect proof, fire retardant and weather resistant. All exterior surfaces are covered with white Laminates. Interior surfaces are epoxy painted. Work table is made of mica top and side panels of thick transparent plexiglass.

Air Flow and Filtration :? Laminar Flow principle involves double filtration of air. Atmospheric air is drawn through pre filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all airborne particles of size 0.3 micron and larger. Double filtered air blows in laminar flow through the work table at designed velocity of 90 ft. min. ? 20%.

Blower Motor Assembly :? Duly balanced, direct drive motor blower units sized to provide adequate air flow volume over the entire surface of HEPA filter. Fitted with reputed make motor and operates with minimum noise level i.e. lower than 65 db on scale and Vibration less than 2.5 um.

Lighting :? Work area properly illuminated by diffused, glare free fluorescent light.

Power Requirement :? 230 V. 1 Phase, 50 Hz, Ac Supply.

Optional Accessories :?
? Satin finish S.S. Table Top (in lieu of Formica Top)
? Transparent front door
? Static Pressure. Inclined Manometer
? Built in U.V. Germicidal light
? Cock for gas, air or vacuum line
? Cold rolled MS Sheet body duly powder coated.
? Stainless steel body duly polished.
? Particle dust count validation at site after installation.

Spare Accessories :?
? HEPA Filter
? Pre Filtern.


See Enlarge



Laminar Flow Clean Air Cabinet : Table Top Model (New)
Click to Enlarge
Laminar Flow Clean Air Cabinet : Table Top Model (New)

These equipment are also horizontal laminar flow cabinets. These are table top models and not floor mounted. These can be easily placed on exiting laboratory platform. However if required, tubular stand can be provided for these laminar flow cabinet & for its work table, if these equipment are to be used as floor mounting design.

Optional Accessories :?
? Satin finish S.S. Table Top (in lieu of Formica Top)
? Transparent front door
? Static Pressure. Inclined Manometer
? Built in U.V. Germicidal light
? Cock for gas, air or vacuum line
? Tubular Stand
? Cold rolled MS Sheet body duly powder coated.
? Stainless steel body duly polished.
? Particle dust count validation at site after installation.

Spare Accessories :?
? HEPA Filter
? Pre Filter


See Enlarge



Vertical Laminar Air Flow Cabinet (Exclusive)
Click to Enlarge
Vertical Laminar Air Flow Cabinet (Exclusive)

Interlabs offers a comprehensive range of high performance Vertical Laminar Flow Clean Air Cabinets. Modular in construction, combining aesthetic appeal with functional utility and efficiency. These are designed to meet the filtration, illumination, Noise & vibration requirements and US Federal Standard 209 B (BS 5295), providing air to meet class 100 (Class I) conditions, to the extent applicable.
These vertical laminar Down Flow configuration find extensive application in Scientific, Medical and Industrial application where a localized high quality clean working environment is essential. These are designed to provide an atmosphere free from airborne particles with Laminar air flow flowing downward the work table.

Construction :? All Laminar Flow Clean Air Cabinets are basically constructed out of thick teak wood board , which is termite and insect proof, fire retardant and weather resistant. All exterior surfaces are covered with white Laminates. Interior surfaces are epoxy painted. Work table is made of mica top and side panels of thick transparent plexiglass

Air Flow and Filtration :? Laminar Flow principle involves double filtration of air. Atmospheric air is drawn through pre filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all airborne particles of size 0.3 micron and larger. Double filtered air blows in laminar flow through the work table at designed velocity of 90 ft. min ? 20%.

Blower Motor Assembly :? Duly balanced, direct drive motor blower units sized to provide adequate air flow volume over the entire surface of HEPA filter. Fitted with reputed make motor and operates with minimum noise level i.e. lower than 65 db on scale and Vibration less than 2.5 um.

Lighting :? Work area properly illuminated by diffused, glare free fluorescent light.

Power Requirement :? 230 V. 1 Phase, 50 Hz, Ac Supply.

Optional Accessories :?
? Satin finish S.S. Table Top (in lieu of Sunmica Top)
? Transparent front door ? Static pressure inclined manometer
? Built in UV Germicidal light
? Cock for gas, air or vacuum line
? Cold rolled MS sheet body of top chamber duly powder coated, available at extra cost.
? Stainless Steel body of top chamber, duly polished, available at extra cost.
? Particle dust count validation at site after installation, at extra cost.

Spare Accessories :?
? HEPA Filter
? Pre Filtern.


See Enlarge



Vertical Laminar Air Flow Cabinets (Exhaust Model) (New)
Click to Enlarge
Vertical Laminar Air Flow Cabinets (Exhaust Model) (New)

These vertical laminar flow cabinets are provided with 100% exhaust system, suitable for exhaust duct upto 6 ft., to throw the contaminated air from the work area into the atmosphere outside the room.
A plenum is provided under the S.S. perforated working table, with exhaust system. The exhaust system works in tandem with the main air flow system. This vertical flow exhaust model is very useful for such applications where environment & personnel protection is required.
HEPA filter & virus burn out can also be provided at the exhaust. The exhaust ducting & the exhaust system for exhaust duct above 6 ft. are also available.

Optional Accessories :?
? Transparent front door
? Static Pressure. Inclined Manometer
? Built in U.V. Germicidal light
? Cock for gas, air, or vacuum line.
? Exhaust system suitable for duct above 6 ft.
? Exhaust ducting.
? Cold rolled M.S. Sheet body duly powder coated, available at extra cost.
? Stainless Steel body duly polished, available at extra cost.
? Particle dust count validation at site after installation, at extra cost.

Spares Accessories :?
? HEPA Filter
? Pre Filter


See Enlarge



Bio Safe Biological Safety Cabinet (Exclusive)
Click to Enlarge
Bio Safe Biological Safety Cabinet (Exclusive)

?Class 100? Laminar Air Flow BIOSAFE Biological Safety Cabinet complies with the guidelines laid down by U.S. National Institute of Health, and the specifications of British Standard 5726 ? Appendix A for class II Biological Safety Cabinets. It is an integral factory assembled system. The basic unit is of externally Melamine laminated body housing, Pre Filters, HEPA Filters & Blowers assembly etc. It is suitable for handling medium to low risk organisms encountered in research, Investigation, Labs in all branches of Medical, Agriculture, Pharmaceutical & Science.

In addition to normal feature of Vertical Laminar Flow, It is provided with following unique features :

  • Re-Circulation of Air ? offering highest level of cleanliness.
  • Sliding Sash ? renders unit convertible for use as a conventional vertical laminar down flow clean air work station.
  • Filtered Exhaust ? protects ambient environment, and avoids build up, air borne particles.
  • Supplementary Air Barrier ? prevents contamination through make up air.
  • Glove Ports and Gauntlets ? permits working with medium to low-risk organisms, pathogenic cultures or unidentified stains that tend to aerosolize in unknown concentrations (Optional).
  • Fumigation Tray ? for effective disinfection/ decontamination (Optional)
  • Built in U.V. Germicidal light ? facilitates sterilization of working area before and after use.
  • Cock ? for gas, air or vacuum, (only 1 no.) is provided.
  • Static Pressure Manometer ? is used for monitoring the HEPA filters.

Supplied complete as above, with cord and plug, suitable to work on 220 volts single phase, 50 Hz, Ac supply.


See Enlarge



Bio Safe Biological Safety Cabinet : Class III
Click to Enlarge
Bio Safe Biological Safety Cabinet : Class III

These class III bio safety cabinets find extensive application in scientific, medical and industrial fields where localised high quality clean air working environment is required in the work zone and at the same time protection of personnel and the environment/atmosphere is required. Its exhaust system ensure 100% exhaust of air from the work area via suitable plenum under the S.S. perforated table, and it works in tandem with the main air flow system. The built in HEPA filter and virus burn out system at exhaust ensures environment protection.
The unit is supplied complete with HEPA filter for work area & for exhaust, pre filters, U.V. Light at work area & exhaust, front door fitted with glove ports, static pressure manometer, gas cock.

Available in following sizes :?
Work area 4??2??2' 6??2??2'

Optional Accessories :?
? Gas burner.
? Exhaust ducting.
? Virus burn out unit.
? Special exhaust system suitable for duct above 6 ft.

Spare Accessories :?
? HEPA filter
? U.V. Tube


See Enlarge




[1]


 

 
 
 
Home|About Us|Products|Certificates|Enquiry|Feedback|FAQ's|Contact Us
Copyright © 2010 - International Biological Laboratories. All rights reserved.
Our Associated Websites
www.interlabs-India.com | www.interlabs.in | www.interlabs.co.in | www.ambalalab.com | www.interlabs.info | www.interlabs-has.com | www.best-visibility.com | www.vidyatechnoart.com | www.labs-glassware.com | www.v-pyrex.com | www.ncert-kits.com | www.shoppingbags.com | www.pharmaceuticalgiftsanatomicalmodels.com
 