[1] |
|
Click to Enlarge
|
Microprocessor UV-VIS Spectrophotometer
Highly Reliable, Accurate, Rugged and Easy to Operate Instrument to Determine Absorbance, %Transmission, Concentration & K Factor
FEATURES
- Printer Interface
- Covers 190 to 1000 nm
- 4 Position Cuvette Holder
- 16 X 2 Line LCD Data Display
- 4 Digit Wavelength Display
- RS - 232C Computer Interface
- µP based wavelength selection
Applications:
The technique of UV / Visible Spectro-Photometry has long been used as a universal laboratory tool covering a wide range of ranging from clinical assays through chemical analysis to water quality monitoring. The technique has enjoyed a molecular biology and the need to quantify DNA and proteins; here, the simplicity of use, the non-destructive nature of the sampling and the cost effectiveness of the measurement has proved very beneficial in the modern laboratory, also, due to new controls on food Standards., Spectrophotometry is the cost effective solution to product quality monitoring in the smaller laboratories.
Specifications:
SPECTRAL |
WAVE LENGTH RANGE |
190 to 1000 nm |
SPECTRAL BANDWIDTH |
2 nm |
ACCURACY |
± 0.5 nm |
READABILITY |
± 0.3 nm |
READ-OUT (WAVELENGTH) |
4 digit 7 segment LED |
PHOTOMETRIC |
PHOTOMETRIC RANGE |
% T : 0 to 100% Abs. : 0 to 1.999 Conc. : 0 to 1.999 K Factor : 0 to 1.999 |
ACCURACY
|
± 0.005 Abs at 1.0 Abs
± 0.010 Abs at 1.5 Abs |
STRAY LIGHT |
Less than 0.1% at 320 nm |
READABILITY |
± 1 count |
DATA READOUT |
16 X 2 Line LCD back lit display |
KEY BOARD |
8 Keys, soft touch membrane type |
DATA STORAGE |
Upto 100 Samples (0-99) |
PRINTER INTERFACE |
Printer Interface for any centronics DotMatrix Printer |
SERIAL INTERFACE |
RS 232C interface (Optional) |
LIGHT SOURCE |
(a) Tungsten – Halogen Lamp (b) Deuterium Lamp (D2) |
DETECTOR |
Wide range silicon Photodiode |
OPTICS |
Complete mirror optics with resolution 1200 grooves / mm grating, Czerny turner mount |
SAMPLE HOLDER |
4 Position adjustable sample holder |
POWER |
230 V ± 10% 50 Hz AC |
DIMENSIONS |
550 X 405 X 130 mm (lxbxh) Approx. |
WEIGHT |
25 Kg. (Approx.) |
ACCESSORIES |
*Quartz cuvetts set of 2 *Dust Cover *Plastic cuvetts set of 4, Operation Manual |
See Enlarge
|
|
|
Click to Enlarge
|
Digital UV-VIS Spectrophotometer
For Reliable & Highly Accurate Determination of Absorbance Transmission & Concentration of Liquids
FEATURES
- Range 190 to 1000nm
- 4 Position Cuvette Holder
- 4 Digit Wavelength Display
- µP Based wavelength selection
- 3½ digit display of %T, Abs & Concentration.
- Highly Accurate and Stable.
Applications
- Clinical
- Food and Drink
- Industrial
- Pharmaceutical
- Biotech
- Molecular Biology
Specifications
SPECTRAL |
RANGE |
190 to 1000 nm |
SPECTRAL BANDWIDTH |
2 nm |
ACCURACY |
± 0.5 nm |
REPEATABILITY |
± 0.3 nm |
READ-OUT |
4 digit 7 segment red LED display of wavelength |
PHOTOMETRIC |
PHOTOMETRIC RANGE |
% T : 0 to 100% Abs. : 0 to 1.999 Conc. : 0 to 1999 |
ACCURACY |
± 0.005 Abs at 1.0 Ab
± 0.010 Abs at 1.5 Abs |
REPEATABILITY |
± 0.002 Abs at 1.0 Abs |
STRAY LIGHT |
Less than 0.1% at 320 nm |
READABILITY |
± 1 count |
DATA READOUT |
31/2 digit 7 segment red LED display of results |
LIGHT SOURCES |
(a) Tungsten – Halogen Lamp (b) Deuterium Lamp |
DETECTOR |
Wide range silicon photo diode |
OPTICS |
Complete Mirror optics with High Resolution 1200 grooves/mm grating, Czerny- Turner mount |
SAMPLE HOLDER |
4 Position sample holder |
POWER |
230V±10% 50Hz, AC |
DIMENSIONS |
550 X 405 X 130 mm (LXBXH) (Approx.) |
WEIGHT |
25 Kg (Approx.) |
ACCESSORIES |
* Quartz Cuvettes of 10mm path length (Set of 2)
* Operation Manual * Dust Cover |
See Enlarge
|
|
|
Click to Enlarge
|
Microprocessor Spectrophotometer
Versatile, Rugged, Accurate & Easy to Operate Instrument to determine Absorbance, Transmission, Concentration and K Factor
FEATURES
- Highly Accurate and stable
- Range 340 to 960 nm
- 16x2 line backlit LCD Display
- Printer Attachment Facility
- Storage for 100 sample
- RS232C Computer Interface (optional)
- Soft touch membrane key
Applications
- Organic compounds in Biological matter
- Glucose, Carbohydrates & Proteins etc., in foods
- Alcohols in Beverages
- Purity of constituents in Pharmaceuticals
- Toxic elements, Cd, Pb, Hg etc. in effluents
Specifications
Wavelength Range |
340 to 960 nm |
Wavelength Resolution |
1 nm |
Wavelength Accuracy |
± 1 nm |
Spectral Slit Width |
< 5 nm |
% Transmission |
0.0 – 100% T |
Absorbance |
0 - 1.999 A |
Concentration |
0 to 19999 |
K-factor |
0.1 to 19999 |
Resolution |
0.1 % T, 0.001 Abs |
Stray Radiant Energy |
± 2% or lesser at 340nm and 400nm |
Photometric Accuracy |
Less than 0.01 Abs |
Monochromator |
600 lines / mm diffraction grating |
Photo Detector |
Wide range silicon photodiode |
Display |
16 X 2 line alphanumeric backlit LCD display |
Key Board |
8 Keys soft touch membrane type |
Data Storage |
Up to 100 samples |
Light Source |
Tungsten – halogen lamp 6V, 10W |
Sample Holder |
10 mm glass cuvettes |
Printer Interface |
Centronics Printer interface for any dot matrix printer |
Computer Interface |
R232C Serial Interface (on request) |
Power supply |
230V± 10% 50Hz AC |
Dimensions |
L490 X B300 X H165mm |
Weight |
8 Kg (Approx.) |
Accessories supplied |
Matched Cuvetts : Aset of 2
Dust Cover : 1 No.
Operation Manual : 1 No. |
See Enlarge
|
|
|
Click to Enlarge
|
Digital Spectrophotometer
FEATURES
- Range 340 to 960nm
- 3½ Digital Display for Data
- Highly Stable & Accurate
- Direct Concentration Facility
Specifications
MODEL |
301 |
RANGE |
340 to 960 nm |
RESOLUTION |
0.1 % t, Abs :0.001 Conc. :1 |
OUTPUT |
% T : 0 to 100 %, Abs: 0 to 1.999, Conc. : 0 to 1999 |
DETECTION |
Silicon Photodiode |
LIGHT SOURCE |
6V, 10W, Tungsten Halogen Lamp |
MONOCHROMATOR |
600 lines / mm holographic grating |
SAMPLE HOLDER |
10 mm Test Tubes |
SPECTRAL BANDWIDTH |
10 nm |
WAVE LENGTH RESOLUTION |
5 nm |
WAVE LENGTH ACCURACY |
± 2.5 nm |
REPEATABILITY |
± 2 nm |
RECORDER OUTPUT |
Available |
DISPLAY |
3 ½ Digit Bright Red LED Display |
OPERATING TEMP. |
50 C to 450C |
POWER |
230V± 10% AC, 50Hz |
DIMENSIONS |
L 490 X B 300 X H 165 mm (Approx.) |
WEIGHT |
8.5 Kg. (Approx.) |
ACCESSORIES |
*Test Tubes (10 mm path length) : 1 set
*Dust Cover : 1 No.
*Operation Manual : 1 No. |
See Enlarge
|
|
|
Click to Enlarge
|
Digital Spectrophotometer
FEATURES
- Range 340 to 960nm
- 3½ Digital Display for Data
- Highly Stable & Accurate
- Direct Concentration Facility
Specifications
MODEL |
301 |
RANGE |
340 to 960 nm |
RESOLUTION |
0.1 % t, Abs :0.001 Conc. :1 |
OUTPUT |
% T : 0 to 100 %, Abs: 0 to 1.999, Conc. : 0 to 1999 |
DETECTION |
Silicon Photodiode |
LIGHT SOURCE |
6V, 10W, Tungsten Halogen Lamp |
MONOCHROMATOR |
600 lines / mm holographic grating |
SAMPLE HOLDER |
10 mm Test Tubes |
SPECTRAL BANDWIDTH |
10 nm |
WAVE LENGTH RESOLUTION |
5 nm |
WAVE LENGTH ACCURACY |
± 2.5 nm |
REPEATABILITY |
± 2 nm |
RECORDER OUTPUT |
Available |
DISPLAY |
3 ½ Digit Bright Red LED Display |
OPERATING TEMP. |
50 C to 450C |
POWER |
230V± 10% AC, 50Hz |
DIMENSIONS |
L 490 X B 300 X H 165 mm (Approx.) |
WEIGHT |
8.5 Kg. (Approx.) |
ACCESSORIES |
*Test Tubes (10 mm path length) : 1 set
*Dust Cover : 1 No.
*Operation Manual : 1 No. |
See Enlarge
|
|
|
Click to Enlarge
|
Digital Spectrophotometer
FEATURES
- Highly Stable & Accurate
- 10mm path length
- Direct Concentration Facility
- Range 340 to 960 nm (Visible)
- Dual Digital Display for Wavelength & Data
- Wavelength Resolution 1 nm
Specifications
MODEL |
305 |
RANGE |
340 TO 960 nm |
RESOLUTION |
0.1 % T, Abs :0.001 Conc. :1 |
OUTPUT |
% T : 0 to 100 %, Abs: 0 to 1.999, Conc. : 0 to 1999 |
DETECTION |
Silicon Photodiode |
LIGHT SOURCE |
6V, 10W, Tungsten Halogen Lamp |
MONOCHROMATOR |
600 lines / mm grating |
SAMPLE HOLDER |
10 mm path length |
SPECTRAL BANDWIDTH |
5 nm |
WAVE LENGTH RESOLUTION |
1 nm |
WAVE LENGTH ACCURACY |
± 2.5 nm |
REPEATABILITY |
± 2 nm |
RECORDER OUTPUT |
Available |
DISPLAY
|
Data : 31/2 digit LED
Wavelength : 4 digit LED display |
POWER |
230V ± 10% AC, 50 Hz |
DIMENSIONS |
L 490 X B 300 X H 165 mm (Approx.) |
WEIGHT |
8.5 Kg. (Approx.) |
ACCESSORIES |
*Test Tubes (10 mm path length) : 1 set
*Dust Cover : 1 No.
*Operation Manual : 1 No. |
See Enlarge
|
|
|
|
|