Logo
Educational tender items for schools in Malaysia
"AVAILABLE ISI STUDENT MICROSCOPE FOR NCERT KITS (UPSKL, SSK, SSLK BIOLOGY)"
 
Product Range
 
News Letter
All Fields are mandatory.
Your Name :
Country :
Your Email ID:
Security Code
 
   
 

Analytical and Scientific Instruments-> Spectrophotometer
 
[1]
 
Microprocessor UV-VIS Spectrophotometer
Click to Enlarge
Microprocessor UV-VIS Spectrophotometer

Highly Reliable, Accurate, Rugged and Easy to Operate Instrument to Determine Absorbance, %Transmission, Concentration & K Factor

FEATURES

  • Printer Interface
  • Covers 190 to 1000 nm
  • 4 Position Cuvette Holder
  • 16 X 2 Line LCD Data Display
  • 4 Digit Wavelength Display
  • RS - 232C Computer Interface
  • µP based wavelength selection

Applications:

The technique of UV / Visible Spectro-Photometry has long been used as a universal laboratory tool covering a wide range of ranging from clinical assays through chemical analysis to water quality monitoring. The technique has enjoyed a molecular biology and the need to quantify DNA and proteins; here, the simplicity of use, the non-destructive nature of the sampling and the cost effectiveness of the measurement has proved very beneficial in the modern laboratory, also, due to new controls on food Standards., Spectrophotometry is the cost effective solution to product quality monitoring in the smaller laboratories.

Specifications:

SPECTRAL

WAVE LENGTH RANGE

190 to 1000 nm

SPECTRAL BANDWIDTH

2 nm
ACCURACY ± 0.5 nm
READABILITY ± 0.3 nm

READ-OUT (WAVELENGTH)

4 digit 7 segment LED
PHOTOMETRIC
PHOTOMETRIC RANGE % T : 0 to 100% Abs. : 0 to 1.999 Conc. : 0 to 1.999 K Factor : 0 to 1.999

ACCURACY

± 0.005 Abs at 1.0 Abs
± 0.010 Abs at 1.5 Abs

STRAY LIGHT

Less than 0.1% at 320 nm
READABILITY ± 1 count
DATA READOUT 16 X 2 Line LCD back lit display

KEY BOARD

8 Keys, soft touch membrane type
DATA STORAGE Upto 100 Samples (0-99)

PRINTER INTERFACE

Printer Interface for any centronics DotMatrix Printer
SERIAL INTERFACE RS 232C interface (Optional)

LIGHT SOURCE

(a) Tungsten – Halogen Lamp (b) Deuterium Lamp (D2)

DETECTOR

Wide range silicon Photodiode

OPTICS

Complete mirror optics with resolution 1200 grooves / mm grating, Czerny turner mount
SAMPLE HOLDER 4 Position adjustable sample holder
POWER 230 V ± 10% 50 Hz AC
DIMENSIONS 550 X 405 X 130 mm (lxbxh) Approx.
WEIGHT 25 Kg. (Approx.)
ACCESSORIES *Quartz cuvetts set of 2 *Dust Cover *Plastic cuvetts set of 4, Operation Manual

See Enlarge



Digital UV-VIS Spectrophotometer
Click to Enlarge
Digital UV-VIS Spectrophotometer

For Reliable & Highly Accurate Determination of Absorbance Transmission & Concentration of Liquids

FEATURES

  • Range 190 to 1000nm
  • 4 Position Cuvette Holder
  • 4 Digit Wavelength Display
  • µP Based wavelength selection
  • 3½ digit display of %T, Abs & Concentration.
  • Highly Accurate and Stable.

Applications

  • Clinical
  • Food and Drink
  • Industrial
  • Pharmaceutical
  • Biotech
  • Molecular Biology

Specifications

SPECTRAL
RANGE 190 to 1000 nm
SPECTRAL BANDWIDTH 2 nm
ACCURACY ± 0.5 nm
REPEATABILITY ± 0.3 nm

READ-OUT

4 digit 7 segment red LED display of wavelength
PHOTOMETRIC
PHOTOMETRIC RANGE % T : 0 to 100% Abs. : 0 to 1.999 Conc. : 0 to 1999
ACCURACY ± 0.005 Abs at 1.0 Ab
± 0.010 Abs at 1.5 Abs
REPEATABILITY ± 0.002 Abs at 1.0 Abs

STRAY LIGHT

Less than 0.1% at 320 nm

READABILITY

± 1 count

DATA READOUT

31/2 digit 7 segment red LED display of results

LIGHT SOURCES

(a) Tungsten – Halogen Lamp (b) Deuterium Lamp

DETECTOR

Wide range silicon photo diode
OPTICS Complete Mirror optics with High Resolution 1200 grooves/mm grating, Czerny- Turner mount
SAMPLE HOLDER 4 Position sample holder
POWER 230V±10% 50Hz, AC
DIMENSIONS 550 X 405 X 130 mm (LXBXH) (Approx.)
WEIGHT 25 Kg (Approx.)
ACCESSORIES * Quartz Cuvettes of 10mm path length (Set of 2)
* Operation Manual * Dust Cover

See Enlarge



Microprocessor Spectrophotometer
Click to Enlarge
Microprocessor Spectrophotometer

Versatile, Rugged, Accurate & Easy to Operate Instrument to determine Absorbance, Transmission, Concentration and K Factor

FEATURES

  • Highly Accurate and stable
  • Range 340 to 960 nm
  • 16x2 line backlit LCD Display
  • Printer Attachment Facility
  • Storage for 100 sample
  • RS232C Computer Interface (optional)
  • Soft touch membrane key

Applications

  • Organic compounds in Biological matter
  • Glucose, Carbohydrates & Proteins etc., in foods
  • Alcohols in Beverages
  • Purity of constituents in Pharmaceuticals
  • Toxic elements, Cd, Pb, Hg etc. in effluents

Specifications

Wavelength Range 340 to 960 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ± 1 nm
Spectral Slit Width < 5 nm
% Transmission 0.0 – 100% T
Absorbance 0 - 1.999 A
Concentration 0 to 19999
K-factor 0.1 to 19999

Resolution

0.1 % T, 0.001 Abs
Stray Radiant Energy ± 2% or lesser at 340nm and 400nm

Photometric Accuracy

Less than 0.01 Abs

Monochromator

600 lines / mm diffraction grating
Photo Detector Wide range silicon photodiode

Display

16 X 2 line alphanumeric backlit LCD display
Key Board 8 Keys soft touch membrane type
Data Storage Up to 100 samples
Light Source Tungsten – halogen lamp 6V, 10W

Sample Holder

10 mm glass cuvettes

Printer Interface

Centronics Printer interface for any dot matrix printer

Computer Interface

R232C Serial Interface (on request)

Power supply

230V± 10% 50Hz AC

Dimensions

L490 X B300 X H165mm

Weight

8 Kg (Approx.)
Accessories supplied Matched Cuvetts : Aset of 2
Dust Cover : 1 No.
Operation Manual : 1 No.

See Enlarge



Digital Spectrophotometer
Click to Enlarge
Digital Spectrophotometer

FEATURES

  • Range 340 to 960nm
  • 3½ Digital Display for Data
  • Highly Stable & Accurate
  • Direct Concentration Facility

Specifications

MODEL 301

RANGE

340 to 960 nm

RESOLUTION

0.1 % t, Abs :0.001 Conc. :1

OUTPUT

% T : 0 to 100 %, Abs: 0 to 1.999, Conc. : 0 to 1999

DETECTION

Silicon Photodiode

LIGHT SOURCE

6V, 10W, Tungsten Halogen Lamp

MONOCHROMATOR

600 lines / mm holographic grating

SAMPLE HOLDER

10 mm Test Tubes

SPECTRAL BANDWIDTH

10 nm

WAVE LENGTH RESOLUTION

5 nm

WAVE LENGTH ACCURACY

± 2.5 nm

REPEATABILITY

± 2 nm

RECORDER OUTPUT

Available

DISPLAY

3 ½ Digit Bright Red LED Display

OPERATING TEMP.

50 C to 450C

POWER

230V± 10% AC, 50Hz

DIMENSIONS

L 490 X B 300 X H 165 mm (Approx.)

WEIGHT

8.5 Kg. (Approx.)

ACCESSORIES

*Test Tubes (10 mm path length) : 1 set
*Dust Cover : 1 No.
*Operation Manual : 1 No.

See Enlarge



Digital Spectrophotometer
Click to Enlarge
Digital Spectrophotometer

FEATURES

  • Range 340 to 960nm
  • 3½ Digital Display for Data
  • Highly Stable & Accurate
  • Direct Concentration Facility

Specifications

MODEL 301

RANGE

340 to 960 nm

RESOLUTION

0.1 % t, Abs :0.001 Conc. :1

OUTPUT

% T : 0 to 100 %, Abs: 0 to 1.999, Conc. : 0 to 1999

DETECTION

Silicon Photodiode

LIGHT SOURCE

6V, 10W, Tungsten Halogen Lamp

MONOCHROMATOR

600 lines / mm holographic grating

SAMPLE HOLDER

10 mm Test Tubes

SPECTRAL BANDWIDTH

10 nm

WAVE LENGTH RESOLUTION

5 nm

WAVE LENGTH ACCURACY

± 2.5 nm

REPEATABILITY

± 2 nm

RECORDER OUTPUT

Available

DISPLAY

3 ½ Digit Bright Red LED Display

OPERATING TEMP.

50 C to 450C

POWER

230V± 10% AC, 50Hz

DIMENSIONS

L 490 X B 300 X H 165 mm (Approx.)

WEIGHT

8.5 Kg. (Approx.)

ACCESSORIES

*Test Tubes (10 mm path length) : 1 set
*Dust Cover : 1 No.
*Operation Manual : 1 No.

See Enlarge



Digital Spectrophotometer
Click to Enlarge
Digital Spectrophotometer

FEATURES

  • Highly Stable & Accurate
  • 10mm path length
  • Direct Concentration Facility
  • Range 340 to 960 nm (Visible)
  • Dual Digital Display for Wavelength & Data
  • Wavelength Resolution 1 nm

Specifications

MODEL

305

RANGE

340 TO 960 nm

RESOLUTION

0.1 % T, Abs :0.001 Conc. :1

OUTPUT

% T : 0 to 100 %, Abs: 0 to 1.999, Conc. : 0 to 1999

DETECTION

Silicon Photodiode

LIGHT SOURCE

6V, 10W, Tungsten Halogen Lamp

MONOCHROMATOR

600 lines / mm grating

SAMPLE HOLDER

10 mm path length

SPECTRAL BANDWIDTH

5 nm

WAVE LENGTH RESOLUTION

1 nm
WAVE LENGTH ACCURACY ± 2.5 nm
REPEATABILITY ± 2 nm

RECORDER OUTPUT

Available

DISPLAY

Data : 31/2 digit LED
Wavelength : 4 digit LED display

POWER

230V ± 10% AC, 50 Hz

DIMENSIONS

L 490 X B 300 X H 165 mm (Approx.)

WEIGHT

8.5 Kg. (Approx.)
ACCESSORIES

*Test Tubes (10 mm path length) : 1 set
*Dust Cover : 1 No.
*Operation Manual : 1 No.


See Enlarge




[1]


 

 
 
 
Home|About Us|Products|Certificates|Enquiry|Feedback|FAQ's|Contact Us
Copyright © 2010 - International Biological Laboratories. All rights reserved.
Our Associated Websites
www.interlabs-India.com | www.interlabs.in | www.interlabs.co.in | www.ambalalab.com | www.interlabs.info | www.interlabs-has.com | www.best-visibility.com | www.vidyatechnoart.com | www.labs-glassware.com | www.v-pyrex.com | www.ncert-kits.com | www.shoppingbags.com | www.pharmaceuticalgiftsanatomicalmodels.com
 
myspace profile views counter