[1]
 
OPEN LOOP MOTOR SPEED CONTROL
Click to Enlarge
OPEN LOOP MOTOR SPEED CONTROL

To study the basic operation of open loop control systems and to study the concept of controller and a control element, set point and dynamic process variable.

Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



CLOSED LOOP MOTOR SPEED CONTROL
Click to Enlarge
CLOSED LOOP MOTOR SPEED CONTROL

Objectives of this experiment:
To study the basic operation of closed loop control systems. Here the controlled variable is measured and fed back to the controller. The Controller then compares the measured value to the desired set point and generates a difference or error signal E=SP-M.

Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



WIRE R.T.D. IN A POTENTIOMETER CIRCUIT
Click to Enlarge
WIRE R.T.D. IN A POTENTIOMETER CIRCUIT

Objectives of this experiment:
In this trainer 2 wire R.T.D is connected in series with the variable calibration resistance
R CAL. The output voltage of potentiometer circuit is taken across the R.T.D and can be applied directly to-the input of the A / D converter.

Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



WIRE R.T.D. USING DC WHEATSTONE'S BRIDGE CIRCUIT
Click to Enlarge
WIRE R.T.D. USING DC WHEATSTONE'S BRIDGE CIRCUIT

Objectives of this experiment:
In this trainer bridge circuit will produce an output voltage that is proportional to the resistance of the R.T.D. RCAL -can be used to calibrate or NULL the bridge output

Built in regulated power supply: +15V/300mA
Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



WIRE THERMISTOR IN A WHEATSTONE'S BRIDGE CIRCUIT
Click to Enlarge
WIRE THERMISTOR IN A WHEATSTONE'S BRIDGE CIRCUIT

Objectives of this experiment:
In this trainer thermistor is generally used as part of dc wheat stones bridge circuit.

Built in regulated power supply: +15V/300mA
Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



WIRE THERMISTOR IN A OP-AMP CIRCUIT
Click to Enlarge
WIRE THERMISTOR IN A OP-AMP CIRCUIT

Objectives of this experiment:
In this trainer one of the feed back resistor in a non-inverting op-amp circuit V0 is given by

Built in regulated power supply: +15V/300mA
Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



TRANSISTOR AS TEMPERATURE SENSOR
Click to Enlarge
TRANSISTOR AS TEMPERATURE SENSOR

Objectives of this experiment:

In this trainer standard general purpose transistor can be used as a temperature sensor. The circuit output voltage Vo is proportional to temperature, since the of the transistor changes with temperature.

Built in regulated: + 9V/300mA
Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



LVDT CHARACTERISTICS
Click to Enlarge
LVDT CHARACTERISTICS

Objectives of this experiment:
To study the LVDT characteristics. The built in 4KHz oscillator generates sine wave. The LVDT produces a difference when we apply Force to it and h is rectified.

Built in regulated power supply: +12V/300mA, -12V/300mA.


See Enlarge



HALL EFFECT CHARACTERISTICS
Click to Enlarge
HALL EFFECT CHARACTERISTICS

Objectives of this experiment:
In this trainer as Rs name implies HALL EFFECT device operates on 'HALL EFFECT' principles. HALL EFFECT occurs as current flows through a semi-conductor material that is under the influence of a magnetic field.

Built in regulated power supply: +(0-16)VDC/300mA
Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



 LDR AS OPTICAL SENSOR
Click to Enlarge
LDR AS OPTICAL SENSOR

Objectives of this experiment:
In this trainer you will study that LDR resistance changes in proportion to light intensity. This causes a corresponding change in the voltage divider output Vout is given by

Built in regulated power supply: +(0-16)VDC/300mA
Input Supply: 230 VAC/50Hz mains operated.
Dimension: 27cms x 17cms x 10cms.
Weight: 500gms


See Enlarge



THERMOCOUPLE CHARACTERISTICS
Click to Enlarge
THERMOCOUPLE CHARACTERISTICS

Objective:-
1.To study the characteristic of transducer
2.To observe the change in output voltage with charge in temp increases.

See Enlarge




[1]


 

 
 
 
Home|About Us|Products|Certificates|Enquiry|Feedback|FAQ's|Contact Us
Copyright © 2010 - International Biological Laboratories. All rights reserved.
Our Associated Websites
www.interlabs-India.com | www.interlabs.in | www.interlabs.co.in | www.ambalalab.com | www.interlabs.info | www.interlabs-has.com | www.best-visibility.com | www.vidyatechnoart.com | www.labs-glassware.com | www.v-pyrex.com | www.ncert-kits.com | www.shoppingbags.com | www.pharmaceuticalgiftsanatomicalmodels.com
 