CONCENTRIC TUBE HEAT EXCHANGER ( plain tube type)
|
To determination of heat transfer rate, LMTD, heat transfer coefficient and effectiveness of heat exchanger. Unit consists of a copper tube inside a G I pipe, hot water from geyser flows through the inner tube and cold water flows through outer tubes. Hot water flows in one direction, cold water can be changed parallel or counter. temperature
and flow rate of water measured.
|
|
|
|