Click to Enlarge
|
REYNOULDS APPARATUS
To demonstrate the principal of laminar and turbulent flow and determination of reynoulds number for various flow rates. A water supply tank to which a glass tube is connected and enters at the center of glass tube cross section. For laminar flow condition, stick is clearly viable but in turbulent flow, the die line diffuse, controlled by valves and gives clear visualization.
See Enlarge
|
|
|
Click to Enlarge
|
VERIFICATION OF BERNOULLIES THEOREM APPARATUS
To calculate the energy & head of water at different saction, A unit consists of a transparent flow channel through which water is made to flow. The velocity of water changes as cross sectional area of channel changes. Changes of head are measured with manometric tubes connected at various tapping to the channel.
See Enlarge
|
|
|
Click to Enlarge
|
FLOW OVER NOTCHES APPARATUS
A flow channel in which notch fitted. Water is supplied at one end of channel, which flows over the notch. A setting chamber with dampers is provided at beginning of flow channel to reduce the pulsations and to settle the flow.arrangement is provided to measure the sill level of water & flow level to determine the head.
See Enlarge
|
|
|
Click to Enlarge
|
FLOW OVER WEIR APPARATUS
A flow channel in which weir fitted. Water is supplied at one end of channel, which flows over the weir. A setting chamber with dampers is provided at beginning of flow channel to reduce the pulsations and to settle the flow. arrangement is provided to measure the sill level of water & flow level to determine the head.
See Enlarge
|
|
|
Click to Enlarge
|
FLOW THROUGH ORIFICE & MOUTHPIECE
To determine Cd, Cc, & Cv, of orifice as well as Cd of mouthpiece. A supply tank to which orifice or mouthpiece fitted. Tank with flow settling arrangement. A tracer pointer to demonstrate & determine x-y Co-ordinates of jet. Arrangement is provided to vary and measure the head over orifice or mouthpiece.
See Enlarge
|
|
|
Click to Enlarge
|
FLOW MEASUREMENT BY VENTURIMETER AND ORIFICEMETER
A unit consists a supply piping connected to a transparent venturi and orifice. tappings to measure pressure difference across venturi and orifice which are connected to differential manometer. The actual flow rate can be measured with the help of measuring tank and both the meters can be calibrated.
See Enlarge
|
|
|
Click to Enlarge
|
LOSSES IN PIPE FITTINGS
To study of loss of head in various pipe fittings, the apparatus consists of a piping providing with a various fittings. A differential manometer supplied to measure the loss of head in these fitting. A flow control valve is provided which enables experimentation at various flow rates. Sufficient settling length for accurate readings.
See Enlarge
|
|
|
Click to Enlarge
|
LOSSES IN PIPE FRICTION
To study the effect of velocity over the head loss. A unit consists of G.I. pipes of same length but two different diameters and one pipe are copper and aluminium each. Piezometric tubes to measure the head at tappings to compare the head losses for various material and pipe diameters.
See Enlarge
|
|
|
Click to Enlarge
|
CENTRIFUGAL PUMP TEST RIG
CONSTANT SPEED ? Centrifugal pump, provided with three phase motor, vacuum gauge at suction and pressure gauge on discharge pipe, gate valve at discharge, which facilities estimation of pump performance at various discharge heads. AC MOTOR & PULLEY TYPE ? As per constant speed type, only pump is provided with a three speed pulley, gate valve at discharge to vary the head. DC MOTOR VARIABLE SPEED ?As per constant speed type, only pump is provided with a variable speed drive and gate value at discharge to vary the speed.
See Enlarge
|
|
|
Click to Enlarge
|
MULTISTAGE CENTRIFUGAL PUMP TEST RIG
Two stage centrifugal pump provided with three phase motor, vacuum gauge at suction & pressure gauge on discharge pipe, pump is a monoblock (I S I Kirloskar) provided with gate valve at discharge which facilities estimation of pump performance at various discharge heads.
See Enlarge
|
|
|
Click to Enlarge
|
CENTRIFUGAL PUMPS IN SERIES & PARALLEL APPARATUS
To study characteristics of pumps in individual or combined operation required head or discharge cannot be obtained by a single pump, two or more pumps are connected is series or parallel, multistage pump in series connection of two pumps which give same discharge at higher head while pumps operating in parallel give higher discharge at same head.
See Enlarge
|
|
|
Click to Enlarge
|
RECIPROCATING PUMP TEST RIG
A recirculating type unit with reciprocating pump and vacuum gauge & pressure gauge at discharge by measuring input to motor and output of pump performance can be estimated at three different speed by using pulley
See Enlarge
|
|
|
Click to Enlarge
|
RECIPROCATING PUMP TEST RIG [DC MOTOR WITH DIMMER CONTROL
A recirculating type unit with reciprocating pump & vacuum gauge & pressure gauge at discharge, by measuring input to motor & output to pump performance can be estimated at different speed by means of one at different heads using dimmerstate.
See Enlarge
|
|
|
Click to Enlarge
|
GEAR PUMP TEST RIG
To determine characteristics ? Speed Vs Discharge, Head Vs Discharge, Discharge Vs Input Power, Discharge Vs efficiency. A recirculating type unit. All the measurements are provided to evaluate the performance of gear pump.
See Enlarge
|
|
|
Click to Enlarge
|
PELTON WHEEL TURBINE TEST RIG - 1.3 HP (1 Kw) Cap.
To, visualise the operation & estimate B. H. P. & W. H. P. and various efficiencies of pelton turbine. Pelton wheel connected to a rope brake. Water supplied by centrifugal pump & flow measured by venturimenter & mercury manometer. Water jet is directed over the buckets by a nozzle & a spare operating inside the nozzle controls the water flow.
See Enlarge
|
|
|