Click to Enlarge
|
DATA LOGGERS
Application : Temperature ( Pressure, Vacuum, pH or any other measurement ) measurement of 8 / 16 / 32 / 48 channels in 1 instrument along with printing output directly printing onto the printer without need for a computer. Data printed directly onto the 80/132 column printer includes date, time, channel number, temperature measured & alarm status of all channels. Options available include computer connectivity ( RS 232, RS 485 ) and modbus with related softwares. Input | Temperature ( RTD Pt - 100 'J' , 'K', thermocouple sensor) Vacuum or Pressure, pH, Humidity DC Current :4 - 20 mA D.C Voltage 0 - 10 V. | Display | 4 1/2 Digit Red L.E.D, 7 segment, 0.56" High. | Resolution | 0.1, 0.01, 0.001 selectable | Scan Time | 1 to 99 sec between channels ( Field Programmable) | Calibration | Software Based for Individual Channel | Relay/ Alarm | 2 Relay Contacts for Alarm & Trip | Print Scan Time | 5 to 9999 sec between succusive printouts. | Alarm | Independent HI / Lo alarams for each channel. | Software (Optional ): | Modchart Data Acquisition Software for Real Time Supervision, historical trend analysis & alarm reports |
See Enlarge
|
|
|
Click to Enlarge
|
Digital Colony Counter
An accurate & easy to operate Instruments for counting of Bacterial & Mould Colonies in Petridishes.
MODEL: SE887
DISPLAY: 3.5 Digital LED
DISH SIZE: 110 mm
MAGNIFICATION: X1.7
POWER: 50 Hz AC
STD: Marking Pen No1
ACCESSORIES: Magnifier Lens 1No. Dust Cover 1No.
110mm Dia Magnifying Glass
Audible Confirmation of each count.
Uniform glare free illumination.
Digital Readout from 0-999(MODEL 361)
Digital Readout from 0-9999(MODEL 362)
Auto Marker Pen.
Woloffhiuegel glass grid with focusing facility.
See Enlarge
|
|
|
Click to Enlarge
|
Digital Photo Colorimeter
MODEL: SE911C
WAVELENGTH RANGE: 400-700 nm
RESOLUTION: 0.01
ABSORBANCE: 0-1.99A
PHOTO DETECTOR: Silicon Photodiode/Photo Cell
DISPLAY: 2.5 digital LED
LIGHT SOURCE: 6.8V,0.3 Amp. Tungsten lamp
SAMPLE SYSTEM: 10mm path length matched glass test tubes
FILTERS: High Std. Glass Filters 8
8 Filters: 400,420,480,500,520,540,620,680 nm.
5 Filters: 420,480,540,620,680 nm.
POWER SUPPLY: 230 V AC,50 Hz.
ACCESSORIES: Test tube set of 5, spare light source,dust cover,instruction manual. See Enlarge
|
|
|
Click to Enlarge
|
Digital Photo Colorimeter
MODEL: SE954C
WAVELENGTH RANGE: 400-700 nm
RESOLUTION: 0.01
ABSORBANCE: 0-1.99A
PHOTO DETECTOR: Silicon Photodiode/Photo Cell
DISPLAY: 2.5 digital LED
LIGHT SOURCE: 6.8V,0.3 Amp. Tungsten lamp
SAMPLE SYSTEM: 10mm path length matched glass test tubes
FILTERS: High Std. Glass Filters 8
8 Filters: 400,420,480,500,520,540,620,680 nm.
5 Filters: 420,480,540,620,680 nm.
POWER SUPPLY: 230 V AC,50 Hz.
ACCESSORIES: Test tube set of 5, spare light source,dust cover,instruction manual. See Enlarge
|
|
|
|